Bootloader CLI AP-800 User Guide
133
If the ipaddrtype is set to static then you need to run the TFTP Server. In this case the TFTP request will be initiated with
the value taken from the parameter "filename". The TFTP request is sent to the IP address set to the parameter
"serverip". In this case the TFTP Server should be reachable to the device.
NOTE: If device fails in any of the above cases, it will bring up the Scantool Interface and wait for scan and change
requests forever.
If we want to access the device with Scantool, then the host running the scantool should also be in the same network as
the device.
Because the scantool broadcast requests will be discarded by the routers if the device and the host running the scantool
are in different network. This reveals that we can not reach the device with the scantool.
A device in bootloader can be recognized by looking at the system description. If the system description does not contain
any build no in braces, conclude that the device is in bootloader mode.
For example:
ORiNOCO AP-800 is the name of the board.
WD is the Regulatory Domain
V1.0.0 is the Bootloader Version
SN-08UC39110110 is the Serial number of the device
Figure B-1 ScanTool View of a Device in Bootloader Mode